How To Light Pilot On Furnace

How To Light Pilot On Furnace

In case your furnace has a pilot mild, it’s possible you’ll have to relight it occasionally. It is a comparatively easy process that you are able to do your self. Nonetheless, you will need to observe the steps rigorously to keep away from any accidents.

Earlier than you begin, guarantee that the furnace is turned off. You also needs to open a window or door to make sure that there may be loads of air flow. Then, find the pilot mild meeting. That is normally a small, metallic tube with a flame burning inside. There shall be a knob or lever that you should utilize to show the gasoline on and off.

After getting positioned the pilot mild meeting, you must flip the gasoline on. To do that, flip the knob or lever clockwise till you hear a click on. You might also have to press a button to ignite the flame. As soon as the flame is lit, you may modify the knob or lever to manage the dimensions of the flame.

Figuring out the Pilot Mild

Finding the pilot mild in your furnace is crucial earlier than making an attempt to mild it. This is an in depth information that can assist you establish the pilot mild:

  • Find the Furnace: The furnace is often positioned within the basement, utility room, or attic. It is normally a big metallic field with pipes and wires connected.
  • Entry the Burner Meeting: Open the entry panel or door on the furnace to reveal the burner meeting. That is the place the pilot mild is often positioned.
  • Determine the Pilot Mild: The pilot mild is normally a small, flame-like burner on the base of the burner meeting. It could be positioned subsequent to a gasoline valve or igniter swap.
  • Distinguish from Different Flames: When you see a number of flames within the burner meeting, be certain that to establish the right one. The pilot mild is often the smallest and most regular flame.
  • Test for a “P” Marking: Some pilot lights have a “P” image or marking etched on them to assist establish them simply.
Ideas for Figuring out the Pilot Mild
Search for a small, blue flame.
Test the situation close to a gasoline valve or igniter swap.
Distinguish from bigger, flickering flames.
Test for a “P” marking on the pilot mild.

Finding the Fuel Valve

To find the gasoline valve on your furnace, observe these steps:

  1. Discover the furnace.
    The furnace is normally positioned in a basement, attic, or utility closet. It’s a giant metallic field with a blower fan and a burner.
  2. Search for the gasoline line.
    The gasoline line is a metallic pipe that runs to the furnace. Will probably be related to a valve on the aspect of the furnace.
  3. Determine the gasoline valve.
    The gasoline valve is a small, brass-colored valve that’s positioned on the gasoline line. It is going to have a lever or a deal with that you should utilize to show it on and off.
Sort of Fuel Valve Location
Handbook Fuel Valve On the gasoline line, close to the furnace
Computerized Fuel Valve Contained in the furnace, close to the burner

Turning Off the Fuel Provide

Earlier than you start working in your furnace, it is important to show off the gasoline provide. It will forestall any gasoline from leaking out and doubtlessly inflicting a fireplace or explosion.

To show off the gasoline provide, observe these steps:

  1. Find the gasoline valve. It is usually positioned close to the furnace or on the gasoline line main into the furnace.
  2. Flip the gasoline valve to the “off” place. That is normally executed by turning the valve clockwise.
  3. Test the gasoline line for any leaks. To do that, apply a soapy water resolution to the gasoline line. When you see any bubbles forming, there is a leak. Restore the leak earlier than continuing.

As soon as you’ve got turned off the gasoline provide, you may safely proceed with lighting the pilot in your furnace.

Fuel Valve Place Description
Open Permits gasoline to circulation by means of the valve
Closed Prevents gasoline from flowing by means of the valve

Lighting the Pilot with a Match

To mild the pilot in your furnace with a match, observe these steps:

  1. Collect your supplies.

    You will have a lighter or match, a long-handled lighter or match holder, and a screwdriver (elective).

  2. Find the pilot mild meeting.

    The pilot mild meeting is normally positioned on the underside of the furnace. It is going to have a small, spherical window and a gasoline valve.

  3. Flip off the gasoline provide.

    Find the gasoline valve on the gasoline line resulting in the furnace. Flip the valve clockwise to show off the gasoline provide.

  4. Mild the pilot mild.

    1. Utilizing a long-handled lighter or match holder, mild a match or lighter.

    2. Maintain the flame close to the pilot mild meeting.

      The pilot mild ought to ignite inside just a few seconds.

    3. If the pilot mild doesn’t ignite, repeat steps 4a and 4b.

      If the pilot mild nonetheless doesn’t ignite, it’s possible you’ll want to make use of a screwdriver to regulate the gasoline valve. Flip the valve counterclockwise barely to extend the gasoline circulation.

  5. Activate the gasoline provide.

    As soon as the pilot mild is lit, flip the gasoline valve counterclockwise to activate the gasoline provide.

  6. Modify the pilot mild flame.

    The pilot mild flame must be about 1/2 inch lengthy. If the flame is just too lengthy, it might trigger the furnace to overheat. If the flame is just too quick, it might exit.

  7. Reassemble the furnace.

    As soon as the pilot mild is lit and adjusted, reassemble the furnace by closing the entry panel.

Lighting the Pilot with an Digital Igniter

In case your furnace has an digital igniter, lighting the pilot is a comparatively easy course of. Listed below are the steps you must observe:

1. Flip Off Fuel Provide

Earlier than you begin, flip off the gasoline provide to the furnace. That is normally executed by turning a valve positioned on the gasoline line.

2. Discover the Pilot Meeting

The pilot meeting is often positioned close to the underside of the furnace. It is going to have a small, spherical window by means of which you’ll be able to see the pilot flame.

3. Flip the Igniter Swap to “On”

Find the igniter swap on the furnace. It is going to normally be a small, pink or black button. Flip the swap to the “On” place.

4. Press and Maintain the Reset Button

As soon as the igniter swap is turned on, press and maintain the reset button. This button is normally positioned close to the igniter swap. Maintain the button for about 30 seconds.

5. Observe the Pilot Flame

After about 30 seconds, you need to see the pilot flame ignite. If the flame doesn’t ignite, wait a couple of minutes and take a look at once more. If the flame nonetheless doesn’t ignite, there could also be an issue with the igniter or the gasoline provide. Contact a certified technician for help.

As soon as the pilot flame is ignited, launch the reset button. The flame ought to stay lit, and the furnace ought to begin heating.

Here’s a desk summarizing the steps for lighting the pilot with an digital igniter:

Step Motion
1 Flip off gasoline provide.
2 Discover the pilot meeting.
3 Flip the igniter swap to “On”.
4 Press and maintain the reset button for 30 seconds.
5 Observe the pilot flame.

Adjusting the Pilot Flame

As soon as you’ve got efficiently lit the pilot flame, it is essential to regulate it for optimum efficiency. Listed below are the steps to take action:

1. Flip On the Fuel Valve

Find the gasoline valve on the furnace and switch it on by turning it counterclockwise. It is best to hear a clicking sound because the gasoline flows into the pilot meeting.

2. Mild the Pilot Flame

Observe the directions within the earlier part to mild the pilot flame utilizing a long-reach lighter or match. Maintain the flame close to the pilot orifice till the burner lights up.

3. Modify the Pilot Flame

Find the pilot adjustment screw close to the pilot burner. It is usually a small screw with a slotted or Phillips head.

4. Use a Screwdriver

Utilizing a screwdriver, gently flip the pilot adjustment screw clockwise or counterclockwise till the pilot flame is roughly 3/4 inches lengthy. That is the optimum flame measurement for many furnaces.

5. Test the Flame Shade

The pilot flame must be blue in coloration. A yellow or orange flame signifies incomplete combustion and must be adjusted till it burns blue.

6. Observe the Flame Stability

The pilot flame must be secure and steady. If it glints or goes out intermittently, it might point out a gasoline provide concern or different issues with the furnace. On this case, it is best to name a certified technician for inspection and restore.

Pilot Flame Shade Indication
Blue Optimum combustion
Yellow/Orange Incomplete combustion, modify flame

Relighting a Extinguished Pilot

In case your furnace’s pilot mild has gone out, you may relight it your self by following these steps:

1. Flip off the gasoline provide to the furnace.

2. Wait 5 minutes for the gasoline to dissipate.

3. Find the pilot mild meeting.

4. Push within the reset button.

5. Maintain down the ignition button and light-weight the pilot mild with a match or lighter.

6. Launch the ignition button and maintain the reset button for 30 seconds.

7. Activate the gasoline provide to the furnace.

If the pilot mild stays lit, your furnace is able to use. If the pilot mild goes out once more, there could also be an issue with the furnace that must be repaired by a certified technician.

Potential Causes of Pilot Mild Extinguishment Options

Clogged or soiled pilot mild orifice

Clear the orifice with a small brush or wire.

Defective thermocouple or thermopile

Change the thermocouple or thermopile.

Blocked gasoline line

Clear the blockage from the gasoline line.

The right way to Mild Pilot on Furnace

1. **Find the pilot mild meeting.** It’s normally positioned close to the underside of the furnace.
2. **Flip off the gasoline provide to the furnace.** That is normally executed by turning a valve positioned close to the gasoline meter.
3. **Wait a couple of minutes for the gasoline to dissipate.** It will assist to forestall an explosion.
4. **Use an extended lighter or match to mild the pilot mild.** Maintain the flame close to the pilot mild meeting and activate the gasoline provide.
5. **Hold the flame on the pilot mild for about 30 seconds.** It will enable the pilot mild to ignite and keep lit.
6. **Activate the furnace.** The furnace ought to now begin to warmth up.

Troubleshooting Widespread Pilot Mild Points

8. The pilot mild will not keep lit.

**Potential causes:**

  • The thermocouple is soiled or broken.
  • The gasoline provide will not be turned on all the way in which.
  • The pilot mild meeting will not be correctly adjusted.

Options:

  1. Clear or substitute the thermocouple.
  2. Activate the gasoline provide all the way in which.
  3. Modify the pilot mild meeting in keeping with the producer’s directions.

In case you are having bother lighting the pilot mild in your furnace, you will need to name a certified technician. A technician can diagnose the issue and guarantee that your furnace is working safely.

Security Precautions for Lighting a Pilot Mild

Earlier than making an attempt to mild a pilot mild, make sure you observe these essential security precautions to attenuate dangers:

1. Test for Fuel Leaks

Previous to igniting the pilot mild, examine all gasoline strains and connections for any leaks. Use a soapy water resolution and apply it to the suspected areas. Bubbles point out a leak, requiring rapid restore by a certified technician.

2. Clear Obstructions

Confirm that the pilot meeting and its environment are free from particles or blockages. Guarantee there’s correct airflow to facilitate ignition.

3. Ventilate the Space

Open home windows and doorways to make sure satisfactory air flow throughout the lighting course of. This prevents gasoline accumulation and potential hazards.

4. Extinguish Flames

Guarantee there are not any open flames or smoking supplies close to the pilot mild space. Exterminate any potential sources of ignition.

5. Follow Warning

By no means try to mild a pilot mild if you’re inexperienced or have any doubts. Search help from a certified technician.

6. Shield Your self

Put on applicable security gear comparable to gloves and security glasses to guard towards potential sparks or scorching surfaces.

7. Observe Producer’s Directions

Check with the producer’s directions for particular procedures on lighting the pilot mild on your specific furnace mannequin.

8. Use the Right Instruments

Make use of the suitable instruments for igniting the pilot mild, comparable to a long-reach lighter or a spark igniter.

9. Lighting the Pilot Mild

Observe these detailed steps to securely mild the pilot mild:

  1. Find the gasoline management valve and switch it to the “Off” place.
  2. Find the pilot meeting and the ignition button.
  3. Depress the ignition button and maintain it whereas concurrently opening the gasoline management valve barely.
  4. Observe the pilot mild by means of the viewing window and ensure if it ignites.
  5. Hold the ignition button depressed for about 30 seconds to permit the thermopile to warmth up.
  6. Launch the ignition button and test if the pilot mild stays lit.
  7. If the pilot mild extinguishes after releasing the ignition button, rigorously repeat steps 4-6.
  8. If unsuccessful after a number of makes an attempt, contact a certified technician for help.
  9. As soon as the pilot mild is lit, modify the gasoline management valve to the specified flame top.

Bear in mind to observe these security precautions and lighting directions diligently to attenuate dangers and make sure the secure and environment friendly operation of your furnace.

Examine and Clear

Repeatedly test the pilot meeting for any grime, particles, or corrosion. Clear the thermocouple and pilot tube utilizing a comfortable brush or compressed air. This helps guarantee correct gasoline circulation and ignition.

Test Fuel Strain

Utilizing a manometer, measure the gasoline strain on the pilot mild. It must be throughout the specified vary on your furnace. If the strain is just too low or excessive, modify it accordingly to make sure optimum flame stability.

Clear Obstructions

Make sure that there are not any obstructions blocking the air consumption or exhaust vents of the furnace. Clear any particles or mud which will hinder correct air circulation and stop the pilot mild from staying lit.

Preserve Correct Airflow

Ample airflow is essential for a secure pilot mild. Examine and clear the blower motor and filter to make sure they’re functioning correctly and offering ample air circulation all through the system.

Tighten Connections

Over time, connections can turn out to be unfastened, inflicting gasoline leaks and interfering with the pilot mild. Tighten all gasoline line connections, together with these on the pilot meeting, gasoline valve, and thermocouple.

Change Thermocouple

The thermocouple generates a small electrical present that retains the gasoline valve open. If the thermocouple fails, the gasoline valve is not going to open, and the pilot mild will exit. Change the thermocouple if it turns into defective.

Modify Pilot Flame

The pilot flame must be a small, regular blue flame. If the flame is just too giant, it could possibly overheat the thermocouple, inflicting it to fail. If the flame is just too small, it might not generate sufficient present to maintain the gasoline valve open. Modify the pilot flame utilizing the adjustment screw on the gasoline valve.

Examine Warmth Exchanger

A cracked or broken warmth exchanger can launch harmful carbon monoxide into the air. Periodically examine the warmth exchanger for any cracks or leaks, and have it repaired or changed if mandatory.

Use Permitted Gas

Solely use the kind of gasoline specified within the furnace handbook. Utilizing an incompatible gasoline can harm the pilot meeting and result in combustion issues.

Name a Certified Technician

In case you are uncomfortable performing any of those duties or encounter any difficulties, it’s advisable to contact a certified HVAC technician who can safely and successfully keep your furnace’s pilot mild.

How To Mild Pilot On Furnace

In case your furnace will not be working, one of many first issues you need to test is the pilot mild. The pilot mild is a small flame that ignites the gasoline in your furnace. If the pilot mild will not be lit, your furnace will be unable to supply warmth.

To mild the pilot mild, you have to an extended match or a lighter. First, find the pilot mild meeting. It’s normally positioned on the backside of the furnace. After getting discovered the pilot mild meeting, flip the gasoline valve to the "off" place. It will cease the circulation of gasoline to the pilot mild.

Subsequent, use the lengthy match or lighter to ignite the pilot mild. Maintain the match or lighter as much as the pilot mild and switch the gasoline valve to the "on" place. The pilot mild ought to ignite instantly. If it doesn’t ignite, strive once more.

As soon as the pilot mild is lit, flip the thermostat to the specified temperature. The furnace will now begin to produce warmth.

Folks Additionally Ask

How do I do know if my furnace pilot mild is out?

In case your furnace will not be producing warmth, the pilot mild could also be out. You’ll be able to test the pilot mild by wanting by means of the sight glass on the furnace. If the pilot mild will not be lit, it can seem darkish.

Why will not my furnace pilot mild keep lit?

There are just a few the reason why your furnace pilot mild might not keep lit. One cause is that the thermocouple could also be defective. The thermocouple is a tool that senses the presence of the pilot mild and sends a sign to the gasoline valve. If the thermocouple is defective, it will be unable to ship a sign to the gasoline valve, and the gasoline valve will shut off the circulation of gasoline to the pilot mild.

Another excuse why your furnace pilot mild might not keep lit is that the gasoline strain could also be too low. If the gasoline strain is just too low, the pilot mild will be unable to remain lit. You’ll be able to test the gasoline strain by utilizing a manometer.

Lastly, your furnace pilot mild might not keep lit if the venturi tube is clogged. The venturi tube is a small tube that mixes air with gasoline. If the venturi tube is clogged, the pilot mild will be unable to get sufficient air to remain lit. You’ll be able to clear the venturi tube by utilizing a small brush.